Amprobe DM-III Multitest 1000A Power Quality Recorder - FREE Delivery!
Sku: I10CZ46PML
Sign up for price alert
300999
Availability:
Out of stock
New
Availability: Out of stock
1780826303
True-rms Measures and records broad spectrum of power quality parameters: AC current, AC voltage to 600V including sags and surges, harmonics (THD and individual up to 49th), active, reactive and apparent power energy, peak demand, power factor, frequency measure Compatible with wide range of current transducers Comes as a complete kit: current transducers, voltage leads, ground probes leads, PC software and download cable are included with this product. Works with single and three phase systems (Y and Delta) Detects and records voltage anomalies, sags and surges Built in scope displays waveforms Phase sequence indication Records up to 64 parameters (single or three phase) simultaneously Manual and programmable recording start Password protection Selectable fundamental frequency of 50 or 60 Hz Special data compression system and user selectable rates allow recording from several hours to several years Download capabilities, Windows compatible PC software Displacement power factor for power factor correction determination Line or battery powered Megohmmeter functions: Tests insulation of wires, cables, transformers and electrical motors Selectable test voltages up to 1000V Programmable timer to perform the dielectric absorption ratio test Sensitive Ohmmeter for checking resistance of motor windings Selectable polarization of ohmmeter for checking grounding continuity Automatic voltmeter protects against misuse on hazardous energized systems Supplied current transducer: DM-CT-HTA 1000A standard CT 2 internal diameter CT +/-(0.5% Rdg + 2 LSD AC Current: DM-CT-100:0.5A to 100A / DM-CT-HTA:5 – 1000A /AM-FLEX33: selectable: 5 – 1000A or 15 – 3000A +/-(0.5% Rdg + 2 LSD) AC Voltage including sags and surges: 0 – 600V +/-(0.5% Rdg + 2 LSD Harmonics: THD, DC and individual up to 49th +/-(0.5% Rdg + 2 LSD) Power: Working (W), reactive (VAR) and apparent (VA) +/-(1.0% Rdg + 2 LSD Energy: Working (kWh), reactive (VARh) and apparent (VAh) +/-(1.0% Rdg + 2 LSD) Peak demand: KW +/-(1.0% Rdg + 2 LSD) Power factor: 0.00 – 1.00 Frequency measurement: 57 to 63.6 Hz at 60Hz fundamental 47 to 53 Hz at 50Hz fundamental +/-(1.0% Rdg + 2 LSD) Phase sequence: 1 – 2 – 3 Co-generation: Computes incoming and outgoing energy Selectable fundamental frequencies: 50/60 Hz Available recording time: Several hours to several years depending on setup Insulation resistance with 50V DC test voltage: 0.01-19.99, 49.9 +/- (2% reading + 2 digits) 49.9 – 99.9MO +/- (5% reading + 2 digits) Insulation resistance with 100V DC test voltage: 0.01-19.99, 99.9 +/- (2% reading + 2 digits) 99.9 – 199.9MO +/- (5% reading + 2 digits) Insulation resistance with 250V DC test voltage: 0.01-19.99, 199.9, 249 +/- (2% reading + 2 digits) 249 – 499MO +/- (5% reading + 2 digits) Insulation resistance with 500V DC test voltage: 0.01-19.99, 199.9, 499 +/- (2% reading + 2 digits) 499 – 999 MO +/- (5% reading + 2 digits) Insulation resistance with 1000V DC test voltage: 0.01-19.99, 199.9, 999 +/- (2% reading + 2 digits) 999 – 1999 MO +/- (5% reading + 2 digits) Low resistance (without timer): 0.01-19.99, 99.9O+/- (2% reading + 2 digits) Low resistance (with timer): 0.01-9.9O+/- (2% reading + 2 digits) Ground resistance: 0-19.99, 199.9, 1999 O +/- (5% reading + 3 digits) Ground resistivity: 0.6- 125.6 Om 0.125-1.256, 19.99, 199.9 kOm +/- (5% reading + 3 digits)