  • True-rms sensing measures active (W), reactive (VAR) and apparent (VA) power with dual-display power factor readout
  • Total harmonics distortion (THD), AC/DC voltage up to 600 V, AC current up to 1000 A, resistance, frequency, temperature
  • Peak hold
  • Optional PC interface capability (RS-232 KIT2)
  • Audible continuity
  • Auto power off
  • Automatic polarity
  • Low battery indication
  • Data hold
  • Large, easy to read LCD display with backlight
  • Accommodates conductors up to 1.77″ (45 mm) in diameter
  • Voltage overload protection for all functions up to 600 V AC/DC
  • AC Current: 40.00 A, 400.0 A, 1000 A
  • AC/DC Voltage: 600.0 V
  • Resistance: 999.9 Ω
  • Temperature: -58 °F → 572 °F (-50 °C → 300 °C)
  • Frequency: 5.00 Hz → 500.0 Hz
  • Active power: (W) 0 kW → 600.0 kW
  • Reactive power (VAR): 0 kVAR → 600.0 kVAR
  • Apparent power (VA): 0 kVA → 600.0 kVA
  • Power Factor: 0.10 → 0.99
  • Total Harmonic Distortion (THD%): 0.0 % → 99 %
  • Accommodates Conductors: up to 1.77″ (45 mm) in diameter
  • TRMS: YES
  • AC Current: 40.0 / 400.0 / 1000 A
  • AC Current Basic Accuracy: +/-(1.0% Rdg + 5 LSD) @ 50 and 60 Hz
  • DC Voltage: 600.0 V
  • DC Voltage Basic Accuracy: +/-(0.5% Rdg + 5 LSD)
  • AC Voltage: 600.0 V
  • AC Voltage Basic Accuracy: +/-(0.5% Rdg + 5 LSD) @ 50 / 60 Hz
  • Resistance: 999.9 Ω
  • Resistance Basic Accuracy: +/-(1.0% Rdg + 6 LSD)
  • Frequency: 5.00 Hz to 500.0 Hz
  • Frequency Basic Accuracy: +/-(0.5% Rdg +4 LSD)
  • THD-F : 0.0% to 99.9%
  • THD-F Basic Accuracy: 1.5% of Reading + 6d @ Fund Frequency
  • Active Power (W): 0 to 600.0 kW
  • Active Power (W) Basic Accuracy: +/-(2.0% Rdg + 6 LSD) @ Harmonics Fund to 10th PF > 0.7
  • Reactive Power (VAR): 0 to 600.0 kVAR
  • Reactive Power (VAR) Basic Accuracy: +/-(2.0% Rdg + 6 LSD) @ Harmonics Fund to 10th PF > 0.7
  • Apparent Power (VA): 0 to 600.0 kVA
  • Apparent Power (VA) Basic Accuracy: +/-(2.0% Rdg + 6 LSD) @ Harmonics Fund to 10th
  • Power Factor: 0.10 to 0.99
  • Power Factor Basic Accuracy: +/- 3 LSD @ Harmonics Fund to 21th
  • Temperature: -58 °F to 572 ° F (-50 ° C to 300 ° C)
  • Temperature Basic Accuracy: +/-(2.0% Rdg + 6 °F) +/-(2.0 % Rdg + 3 °C)
Stock Request Notify When Available

The Amprobe ACD-41PQ provides a simple and effective way to verify if the electrical system is affected by harmonics. Add on troubleshooting capabilities with the ACD-40PQ data-logging feature or get complete power analysis with the ACD-41PQ. Increase measuring efficiency with an optional PC interface kit.

THD-F is defined as: (Total Harmonic RMS / Fundamental RMS) x 100%

In the Box

  • Amprobe ACD-41PQ 1000A Power Quality Clamp Meter with Temperature
  • Carrying Case
  • Test Leads
  • Batteries (Installed)
  • Type-K Thermocouple